VSH8xD – Vacuum Furnaces

Vacuum Transducer ● RS485 ● Pirani/ Hot Cathode ● 1000 to 5e-10 mbar

The digital combination vacuum transducer VSH (Pirani/hot cathode) measures absolute pressure from atmospheric pressure to ultrahigh vacuum.Brazing, sintering or annealing of metals require an atmosphere free of oxygen. Therefore such processes are carried out under vacuum, partially using inert gas.

Challenge

The vacuum level must be monitored and kept constantly low during the process in order to avoid oxidation of the products. Our client had to measure the pressure in his high vacuum tube furnace near the gas inlet as well as at the vacuum port with high accuracy.

  • Wide range combination sensor Pirani / Bayard Alpert
  • Bayard Alpert with blowing resistant, yttrium coated double filament
  • Longterm tests confirm excellent life time: up to 100,000 shock venting cycles

Solution

Two VSH transducers have the required wide measuring range and detect the pressure at the furnaces gas inlet and vacuum port with excellent precision. They are linked to the system PLC by their serial RS485 interfaces, so that both pressure levels can be directly visualized in a diagram. This allows to easily monitoring the pressure gradient inside the furnace tube.

Description
Weight 1.1 kg
Dimensions 25 x 16 x 9 cm
Gas dependency depending on gas type
Measurement range mbar 1000 – 5e-10 mbar
Measurement range Torr 750 – 5.0e-10 Torr
max. overload 4 bar abs.
Accuracy 1000 … 10 mbar: ca. 30 % f. r. | 10 … 1e-8 mbar: 10 % f. r.
Repeatability 10 – 1e-2 mbar: 2 % f. r. | 1e-2 – 1e-8 mbar: 5% f. r.
Materials in contact with vacuum Stainl. steel 1.4307, tungsten, nickel, glass, platinum, iridium, yttria oxide
Filaments / anodes Yttria coated iridium
Emission current 9 μA, 100 μA, 1.0 mA, 2,0 mA
Degas method Ohmic heating of the anode
Response time 50 ms (switching of emission current
Operating temperature +5…+60 °C
Storage temperature -40…+65 °C
Bake out temperature Max. 180°C at the flange (voltage supply switched-off)
Voltage supply 20 – 30 VDC
Power consumption Max. 8 W, add. 1 W f. Degas, 0,8 W f. Relais/LCD, add. 1,8 W f. Profinet
Output Singal SL 0 – 10 VDC, min. 10 kΩ, measuring range 1,219 – 8,6 VDC, log. except EtherCAT, Profinet
Serial interface RS485: 9.6 kBd to 115 kBd, 8 databit, 1 stopbit, no parity
Switching output 2x relay, pot. free, 50 VAC / 2 Aor 30 VDC / 2 A, max. 60 VA, except EtherCAT and Profinet
Electrical connection SubD 15pole, male
Article Number (choice of vacuum connection): DN 25 ISO-KF (VSH87), DN 40 CF-F (VSH89), DN 40 ISO-KF (VSH88)
Dimensions 141 x 69 x 48 mm (VSH88)
Protection class IP40, IP54 mit connector XB15SL05
Weight 475 g (VSH88)
Additional information
Brands

Thyracont Vacuum Instruments

Select Model

DN 25 ISO-KF (VSH87)

,

DN 40 CF-F (VSH89)

,

DN 40 ISO-KF (VSH88)