Weight | 0.098 kg |
---|---|
Dimensions | 3 x 3 x 6.6 cm |
Measurement principle | Heat conduction Pirani, Heat conduction Pirani (impulse Pirani) |
Gas dependency | depending on gas type |
Measurement range mbar | 1000 – 1e-4 mbar |
Measurement range Torr | 750 – 1e-4 Torr |
max. overload | 10 bar abs., 16 bar abs. with CERT31P |
Materials in contact with vacuum | Stainless steel 1.4307, tungsten, nickel, glass |
Accuracy | 1000 – 20 mbar: ca. 30 % f. r. | 20 – 0.002 mbar: 10 % f. r. |
Repeatability | 20 – 0.002 mbar: 2 % f. r. |
Response time | 200 ms |
Voltage supply | 15 – 30 VDC |
Electrical connection | Type Hirschmann, 6pin, male, lockable |
Power consumption | Max. 1 W with 24 VDC supply voltage |
Operating temperature | +5…+60 °C |
Storage temperature | -20…+70 °C |
Bake out temperature | Max. 150°C at the flange (transducer separated from voltage supply) |
Output signal | 0-10 V |
Article Number (choice of vacuum connection): | DN 16 CF (VSP64MV), DN 16 ISO-KF (VSP63MV) |
Dimensions | 66 x 30 x 30 mm |
Protection class | IP40 |
Weight | 135 g (DN 16 CF), 98 g (DN16 ISO-KF) |
VSP6xMV – Carbonated Beverages
Vacuum Transducer ● 1000 bto 1e-4 mbar ● 0-10V output
The Analogline VSP is based on a new, patented measurement principle. The well proven Thyracont impulse Pirani sensor provides a larger measuring range with higher resolution.
It uses an optimized temperature compensation. Accuracy and stability have been further improved.
Carbon dioxide gas is used for the industrial production of carbonated beverages. This extends shelf life and the beverage tastes fresh and sparkling.
Challenge
Because the gas gets in contact with many different substances during its fabrication, the end product can still be flawed with rests of contamination. To assure proper quality of the carbonated beverage production it is essential to monitor the pureness of the carbon dioxide by means of a spectrometer alignment. Since detection limits for gas components like carbon monoxide, methane or hydrogen sulphide usually are in the range of less than 0.01 ppm the spectrometers must operate with high accuracy and reliability.
Solution
Periodic offset adjustment under fine vacuum conditions guarantees that even slightest hints of contamination can be detected. The precise VSP63MV Pirani vacuum transducer controls whether the required vacuum level for zero adjustment is achieved. With its elastic helix filament and the rugged metal housing the transducer is especially durable.
Benefits at a Glance
- Small dimensions
- Elastic helix filament
- Rugged metal housing