A2075 SONET

Noncontact ultrasonic scanner-flaw detector А2075 SoNet is applicable for automatic flaws search in the metal pipe’s walls of 1020 ÷ 1420 mm in diameter and with thickness starting from 6mm.

Operating principle of the scanner- flaw detector is a wave guided pulse echo inspection technique excitation (sending) and receiving of ultrasonic waves in a pipe’s body is made without a contact (without using a couplant) with a help of electro-magnetic acoustic (EMA) transducers.

Detection of a stress-corrosion and corrosion flaws in the pipe’s body. Detection of flaws in flats (sheet products) with indication of flaw’s quantity, relative dimensions and locations (coordinates).

Wi-Fi connection between the PC and the scanner-flaw detector provides a great mobility and the possibility for the operator to conduct testing remotely.

An image of a pipe section is made right during the scanning that helps to estimate the flaws found and helps to decide if an additional inspection with the other NDT methods is necessary.

Continuing documentation of the results as a scanning image of the pipe.

Efficient review of the collected scan images in the screen of the Notebook.

Post-processing of the scan images along with recording of the location, orientation and the type of the flaws.
Time required to set up the instrument and start inspection is just 3 minutes.

The possibility to upload the data from intratubal inspection and attach it to the main report.

Block structure of the instrument makes it possible to promptly replace a broken blocks on-the-site by only one operator.

Portability – the scanner – flaw detector can be carried by 2 people and can be operated by 1 user.

Description
Velocity 3020 m/s
Operating frequency 0.5 MHz
Range of the calibrated amplifier 0-40 dB
Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws along the circumference of the pipe, not more than ±100 mm
Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws towards the pipe, not more than ±20 mm
Maximum sensitivity of the receiver, not less than 20 mKV
Measurement accuracy of the amplitude ratio of signals at the receiver input, not more than ±1 dB
Power Accumulator blocks
Voltage 12 V
Operating time (accumulator) 8 h
Weight 42 kg
Average error-free running time 30000 hours
Average lifetime, not less than 4 years
Operation conditions: air temperature from -40 to +50°C
relative air humidity at a temperature of +35 °С, not more than 95%
Dimensions 407 х 655 х 407 mm
Additional information
Brands

ACS Instruments